Learn To Fix EMC Problem Easily And In Your Lab Troubleshooting Radiated Emissions, Min Zhang
Troubleshooting EMC problem can be done directly in your lab before going into an EMC test house. Practical example in this video fixing Radiated Emission issue of a Flyback Power supply. Thank you very much Min Zhang. Links: Contact Min: Possibly interested in the Min s EMC course Just fill up this form: PDF presentation used in the video: Min s company website: More information: Chapters: 00:00 What is this video about 02:27 EMC precompliance setup in your lab 12:14 The first steps to try after seeing EMC problems 13:15 Shorter cable and why it influences EMC results 18:44 Adding a ferrite on the cable 23:32 What causes radiation 27:18 Flyback Converter, SMPS (Switching Mode Power Supply) 29:26 Using TEM Cell for EMC troubleshooting 33:04 Benchmark test with TEM Cell 35:02 Improving input capacitors 43:20 Sh
|
|